TimeLord-Net - Next Generation Reference-locked NTP Master Clock System

TimeLord-Net Front Panel

The industry-standard TimeLord-Net Master Time Source has been re-designed and re-engineered to take advantage of the latest advances in technology. It is now modular in design and provides a complete precision time synchronisation solution for computer networks, CCTV security, CCC/C3, digital clock systems, analogue clocks (with hands), industrial process control, voice recording and many other applications requiring accurate time synchronisation of equipment. It supersedes the previous TimeLord-Lite range providing extra functionality at a lower price.

The TimeLord-Net may be used in stand-alone mode, deriving its timekeeping from its accurate, high stability, internal crystal oscillator or, for ultimate precision, synchronised via optional receivers to GPS satellites or DCF and MSF terrestrial radio time code transmitters.

The TimeLord can be synchronised to any of the following Time References Inputs as standard with the appropriate receiver head:

V-488C GPS
  • GPS Satellite Time Reference
  • GLONASS Satellite Time Reference - also in GLONASS-with-GPS assistance mode
  • MSF Atomic Reference - BST (British Standard Time) - UK (now in Cumbria - was Rugby)
  • DCF Atomic Reference - CET (Central European Time) - Germany (Mainflingen nr Frankfurt)
  • NTP Network Time Protocol from remote NTP Time Server located on the same TCP/IP Network including the internet
  • SNTP Simple Network Time Protocol from remote NTP Time Server located on the same TCP/IP Network including the internet

The following Optional Input Interface Modules are also available:

  • SYNC2-IN Additional Receiver-Head Synchronisation Interface allows connection of two receiver heads for dual redundant functionality
  • AF-IN Audio-Input Interface allow synchronisation from IRIG-B or EBU-LTC Timecode
  • OPT-IN ST Fibre-Optic Input Interface to allow synchronisation from optically-connected time code signals

The TimeLord provides the following Data Output Interfaces as standard:

  • V-Code Configurable single V-Code Output for either 482 Multi-Zone Time/Date code for Digital Clocks, Active MSF, Active DCF or 24V bi-phase Impulses for Analogue Clocks (with hands)
  • Serial RS232 and RS422/RS485 Serial Outputs which can transmit one of more than 85 different serial ASCII time-and-date telegrams in user-selected formats and intervals
  • 1PPS High-Accuracy 1PPS Pulse-per-second Output at RS-232 levels
  • Ethernet 10/100Base-T Ethernet RJ45 NTP network interface.

The following Optional Output Interface Modules are also available:

  • AF-OUT Dual Audio Time Code outputs for EBU LTC TimeCode or modulated IRIG-B
  • SER-OUT Dual RS-232/RS-485 Serial Interface (in addition to the in-built serial port)
  • OPT-OUT Dual ST Fibre-optic output either demodulated IRIG-B, EBU LTC Timecode or Serial ASCII data
  • RLY-OUT Dual Programmable Relays (mains-rated)
  • PPS-OUT High Voltage (110V DC) PPS Pulse-per-second PPS Periodic Outputs
  • DEM-OUT 4x Mirrored logic level outputs for IRIG-B, EBU-LTC, MSF or DCF Timecodes, PPS or other Periodic signals

POWER OPTIONS

  • Single Mains Input is standard
  • DUAL-AC Dual redundant universal mains power supply (Optional)
  • 24V-IN Isolated 24VDC Input (Optional)
TimeLord-Net Front Panel

OVERVIEW

The NEW Timelord-Net NTP Master Time Source is housed in a 1U high 19" rack mount case and provides time data outputs for computer networks, digital displays, analogue clocks (with hands) and virtually anything that requires an accurate time-stamp. A 2-U version is available to accommodate additional optional input and output modules. The high-visibility 6-digit red LED display can show time or date, has adjustable brightness and can be read at distances of up to 7m. The TimeLord-Net is delivered pre-programmed with a 256-year calendar that includes daylight savings changes for all the 90+ Time Zones worldwide - plus custom time zones can be manually programmed if required. Programming is simply accomplished via an intuitive setup menu, using the 4 buttons on the front panel.

Timebase

The internal, high stability, TCXO Temperature-Compensated Quartz Crystal Oscillator typically provides an accuracy of ±0.1 seconds per day @ 0-45°C (approximately ±2 seconds per month). The free-running accuracy of the oscillator is automatically trimmed over a long time period when the TimeLord is referenced to an external atomic reference to further improve the free-run accuracy.

With the optional TCXO-HQ installed, the free-running accuracy is further improved to typically ±0.01 seconds per day @ 0-45°C (approximately ±0.2 seconds per month = ±2½ seconds per year approx)

When synchronised with the GPS satellite network via the optional V-488C.00 GPS receiver system, the RS232 level 1PPS 'on-time' pulse is maintained typically within 10µS of UTC.
When synchronised with DCF or MSF Radio Time Code Transmissions, via an optional V-484 series time code receiver, the Timelord-Net output signals are maintained within 30mS of UTC.
When synchronised to an NTP Time Source (setup as an NTP Client), the Timelord-Net Time Source output signals are maintained within 1-10mS of the NTP Source depending on network delay and jitter.

The TimeLord-Net Master Time Source has a 250-year internal calendar with 4-digit year setting, including for each time zone, offset from UTC and daylight savings change information. A simple "set-once" Time Zone Setup facility for any location in the world is provided, automatically calculating the appropriate time offsets from UTC and future seasonal time changes.


OPTIONAL INPUT INTERFACES

SYNC2-IN allows connection of a 2nd Receiver Head to provide dual redundant functionality. The 2nd Receiver Head may use the same or a different atomic reference and the TimeLord will only change to the backup off-air reference in if the main reference fails and if the backup which is validated during the synchronization process.

AF-IN Audio-Input Interface allows synchronisation from a modulated audio time reference, including IRIG-B – commonly-used in industrial, marine and aviation time-keeping applications – and EBU-LTC longitudinal Timecode commonly-used for Broadcast and CCTV/Security.

OPT-IN ST Fibre-Optic Input Interfaces allows synchronisation from optically-connected time code signals including demodulated IRIG, EBU and Serial Time data.


STANDARD REFERENCE INPUT INTERFACE CONFIGURATION

OFF-AIR RECEIVER INPUT
2-part terminal block provides twisted-pair interface to Receiver Head and power for GPS (screw terminals - 4-way) and separate RJ45 for NTP-locking

  • GPS Satellite Time Reference - uses V-488C.00 GPS Antenna / Interface with twisted pair connection (coax/triax not needed)
  • MSF Atomic Reference - BST (British Standard Time) - UK (now in Cumbria - was Rugby) - uses V-484.02 Receiver Head - with twisted pair connection
  • DCF Atomic Reference - CET (Central European Time) - Germany (Mainflingen nr Frankfurt) - uses V-484.03 Receiver Head - with twisted pair connection

NTP NETWORK TIME INPUT An RJ45 connector provides an Ethernet connection for NTP-locking

NTP NETWORK TIME PROTOCOLS SUPPORTED
  • NTP Network Time Protocol from remote NTP Time Server located on the same TCP/IP Network including the internet - uses RJ45 Ethernet Connection
  • SNTP Simple Network Time Protocol from remote NTP Time Server located on the same TCP/IP Network including the internet - uses RJ45 Ethernet Connection

STANDARD OUTPUT INTERFACE CONFIGURATION

NTP OUTPUT
An RJ45 connector provides an Ethernet connection for NTP output

NTP NETWORK TIME PROTOCOLS SUPPORTED
  • NTP Network Time Protocol (NTP) v2, v3 and v4 clients are supported in both unicast and broadcast modes of operation (RFC1305 & RFC1119)
  • SNTP Simple Network Time Protocol (SNTP) v3 and v4 clients are supported in both unicast and broadcast modes of operation (RFC2030 & and RFC1769C)
  • TIME TIME Protocol (RFC868) is supported in UDP and TCP Modes
  • DAYTIME DAYTIME Protocol is supported in UDP and TCP Modes

RELAY CONTACTS
Changeover relay contacts are provided rated at 30VDC @ 500mA. The relay can be programmed by the user to changeover for one second at various repetition rates:

  • Every 5 seconds
  • Every minute
  • Every hour
  • Once per day at a user programmable time

The relay can also be programmed by the user to changeover on the occurrence of specific events:

  • On power failure
  • While locked to an external time reference
  • During an error state

V-Code CONGIFURABLE OUTPUT/s (one v-Code output is standard; 2nd optional)
Configurable for either 482 15-zone Time-and-Date Code for Digital Displays or as an Intelligent Impulse Output Driver for Analogue Clocks (with hands). V-401A Range

482 Multi-Zone Time-and-Date Code is intended for the control and synchronisation of 400A series digital clocks and time-zone displays showing time and date in up to fifteen different time zones. The data code itself is extremely robust and can be sent many hundreds of metres without problem and comprises an accurate minute-edge followed by a 15-zone "time-telegram" sent every minute. One Timelord-Net unit can control up to fifty V-400A series slave displays located up to 1km from the TimeLord unit using a simple, non-critical, single cable pair. The appropriate UTC offset and all future seasonal time changes are pre-programmed for almost every global location. Up to 50x V-400A series clocks can be connected to a single v-Code Output.

Impulse Clock for TimeLord

Intelligent Impulse Output Bi-Phase impulses to drive Impulse Analogue Clocks (with hands) can be produced by the TimeLord-Net which automatically corrects for daylight saving changes and also catches up when the mains fails. At setup, all the clocks on the same impulse output are manually moved to show the same time and that time is entered into the TimeLord Master Clock. 3x Forward pulses are then sent from the TimeLord and the wiring to any clock that has advanced by two steps should be changed round to ensure that all the clocks "tick" and "tock" together. The TimeLord is then set to RUN and the clocks on that impulse output either speed forward to catch up, or wait until that time arrives - whichever is faster - before moving forward at normal speed (either 1 pulse per second, one every half minute or one every minute internally settable). If there is a problem with the mains or the clock loop somehow becomes overloaded, all the clocks are stopped together (as opposed to some running and others not as the power reserve dies) and the TimeLord remembers that time. When the mains returns, the clocks all step forward at fast speed to catch up. It is worth providing a UPS for the TimeLord to keep the impulse clocks running case of prolonged mains failure; the TimeLord's internal battery maintains timekeeping for around 1 year but outputs are disabled to conserve battery energy.


OPTIONAL OUTPUT INTERFACES

AF-OUT Dual Audio Time Code outputs for EBU LTC TimeCode or modulated IRIG-B
The optional AF-OUT output interface adds two flexible Audio outputs that can be independently configured to provide either 1kHz modulated IRIG-B timecode for the synchronisation of voice recorders, data- logging and distributed control equipment, or EBU Longitudinal TimeCode for use in Broadcast, Secirity, CCTV and other applications. IRIG is normally transmitted as a modulated 1kHz signal at a 100Hz bit-rate and contains day-of-year, hours, minutes and seconds information. EBU Timecode is a self-clocking audio signal at 2kbps with each frame of data comprising 80 bits. Each timecode frame contains time, user information plus count-up and count-down information as well as user-programmable information. The time data includes hours, minutes, seconds and video frames (25 per second) and the user bits allow date and other information embedded within the timecode frame. The date format carried in the TimeLord EBU User-Bits signal can be set to one of two commonly-used standards for Broadcasting. The audio outputs are presented on BNC connectors and the interface is 600 ohm transformer-balanced which can be used to feed both balanced and unbalanced devices.

SER-OUT Dual RS-232/RS-485 Serial Interface (in addition to the in-built serial port)
The optional SER-OUT provides two additional RS232 and RS422/RS485 interfaces each of which can be programmed to provide one of more than 85 different serial ASCII time and date telegram message formats to be selected by the user.
General purpose serial data formats are user configurable for:

  • 7 or 8 data bits
  • Odd, even or no parity
  • 1200, 2400, 4800, 9600 or 19200 baud rate
  • The message output repetition rate is programmable for once per second, per minute, per five minutes, per hour, per day or on request

OPT-OUT Dual Optical Outputs
The optional OPT-OUT provides Dual ST Fibre-Optic outputs configured for demodulated IRIG-B, EBU Timecode or Serial ASCII Data. The connectors are ST-type designed for 62.5/125µm (820nm) fibre.

RLY-OUT Dual Programmable Relays (mains-rated)
The optional RLY-OUT provides dual 230V mains AC relays for the periodic signalling of error conditions and control of third-party equipment

PPS-OUT PPS Pulse-per-second PPS Periodic Outputs
The optional PPS-OUT provides dual High-Voltage pulse-per-second periodic outputs rated at 110V DC

DEM-OUT Demodulated Outputs
The optional DEM-OUT provides Quad logic level outputs that can be programmed to mirror either IRIG-B, EBU-LTC, MSF or DCF Timecodes, PPS or other Periodic signals

TimeLord-Net Rear Panel Drawing

V-400 series digital clocks and TimeLord Master Clocks, when used in accordance with our recommendations, comply with the European Community Electromagnetic Compatibility Directive 2004/108/EC, Low Voltage Directive 2006/95/EC and RoHS2 Directive 2011/65/EU and conform to the following standards:

  • EN 50121-4-2006
  • EN 61000-6-2:2005
  • EN 61000-6-4:2007+A1:2011
  • EN 55022:2010
  • EN55024:2010
  • EN 60950-1:2006
Specifications
Timing Accuracy:
Free-Run High stability, self-calibrating quartz crystal oscillator - Timekeeping accuracy to within about 0.1 seconds per day, 18-22°C (approximately ±2 seconds per month)
With Optional TCXO-HQ Ultra-High stability, self-calibrating quartz crystal oscillator - Timekeeping accuracy better than 0.1 sec/day @ 45°C (approximately ±2 seconds per month)
Locked to MSF or DCF Using V-484 OFF-AIR receiver - Timekeeping accuracy is typically within 30ms of UTC
Locked to GPS or GLONASS Using V-488C Satellite Receiver - Timekeeping accuracy is typically within 30ms of UTC
Reference Inputs:
(Off-Air Receivers)
V-488.00C GPS receiver system GPS Satellite system includes active antenna which must have 80% view of the sky to lock up, integral receiver / interface which is remotely powered by the TimeLord which may be located up to 200m distant - 25m cable included. Timekeeping accuracy to within 10ms of UTC. Connection to the TimeLord is using 4-core twisted-pair (no Coax or Triax cable needed)
V-488.00C-GL GLONASS receiver system GLONASS Satellite system includes active antenna which must have 80% view of the sky to lock up, integral receiver / interface which is remotely powered by the TimeLord which may be located up to 200m distant - 25m cable included. Timekeeping accuracy to within 10ms of UTC. Can operate in GLONASS or GLONASS-with-GPS assistance syncrhonisation modes. Connection to the TimeLord is using 4-core twisted-pair (no Coax or Triax cable needed)
V-484.02 MSF (Cumbria - was Rugby) receiver GMT/BST receiver - omni-directional high sensitivity wallmount in IP65 ABS case. Timekeeping accuracy to within 30ms of UTC
V-484.03 DCF (Frankfurt) receiver CET/CEST receiver - omni-directional high sensitivity wallmount in IP65 ABS case. Timekeeping accuracy to within 30ms of UTC
Internal timebase (free-run mode) High stability quartz crystal oscillator. Timekeeping accuracy to within about 0.1 seconds per day, 18-22°C (approximately ±2 seconds per month)
Optional Reference Input Interfaces:
SYNC2-IN Additional Receiver-Head Synchronisation Interface - allows connection of two Receiver Heads for dual redundant functionality
AF-IN Audio-Input Interface - allows syncrhonisation from IRIG-B or EBU-LTC Timecodes
OPT-IN ST Fibre-Optic Input Interface to allow synchronisation from optically-connected timecode signals
Standard Outputs:
Serial data signals RS-232 and RS-422/RS-485 on D-9F connector
Serial data format 7/8 bit, even, odd or no parity, 1200-19200 baud
Serial data messages Date and / or time in various formats, 85+ standard serial time data message formats are preprogrammed and can be menu selected
Repetition rate 1 sec, 1 min, 5 mins, 1 hour, 24 hours or on request
Serial 'on-time' signal RS232 level signal every second
V-Code Outputs One Output is standard TimeLord-Net, 2nd Output Optional - twisted pair on screw terminals
Separately user-configurable for 482 Time / date code for up to 50x V-400A digital displays with 15 managed time zones or
Dual Intelligent Impulse Output for up to 50x Analogue displays (with hands)
Number of digital displays Up to 50 clocks / multi-zone displays on up to 1km cable
Number of impulse clocks Up to 50 clocks (impedance >3600R) wired in parallel depending on cable
Optional Output Interfaces:
v-CODE-OUT Additional programmable output for either 482 Time-and-Date Code for Digital Displays or Intelligent Impulse Output for Analogue Clocks (with hands).
Can drive up to 50 digital displays or impulse clocks
Up to 2x v-Code Outputs are possible in the standard 1-U version of the TimeLord; up to 4x v-Code Outputs in the 2-U version
AF-OUT Dual Audio Time Code Outputs for EBU LTC Timecode or modulated IRIG-B
supports IRIG-B (B123), IRIG-E (E123), Afnor NFS 87-500, NEMA 911, IEEE 1344 (see manual regarding IEEE 1344 extensions implemented)
SER-OUT Dual RS-232 and RS422/RS485 Serial Outputs (in addition to the in-built serial port) which can transmit one of more than 85 different serial ASCII time-and-date telegrams in user-selected formats and intervals
OPT-OUT Dual ST Fibre-Optic Output Interface either demodulated IRIG-B, EBU LTC TImecode or Serial ASCII data
RLY-OUT Dual Programmable Relays (mains-rated)
PPS-OUT High-Voltage (110V DC) PPS Pulse-per-Second Periodic Outputs
DEM-OUT 4x Mirrored logic-level outputs for IRIG-B, EBU-LTC, MSF or DCF TimeCodes, PPS or other Periodic Signals
Front Panel:
(Controls and Indicators)
LED clock display HH:MM:SS / DD:MM:YY switchable with Locked to Off-Air LED
Hi-Brite Red 7-segment digits 20mm high
Parameter setup Time / date / time zones (15) / serial data via 4 pushbuttons
LED indicators LEDs to show serial OK / not OK, timecode date mode (1,2,3), timecode O/P
Accessories:
Cables (included) IEC mains power cord
RS-232 serial cable
Software utilities
(available separately)
ClockLok software for running on computers to lock their internal clocks to the TimeLord serial time data output
SchedulePak Programmable Timer package for running on a PC to provide GPI relay trigger outputs
Physical:
Dimensions 1-U version 441 x 43 x 275mm (WxHxD)
2-U version with space for additional optional interfaces
441 x 44.4 x 275mm (WxHxD)
Weight 2.5kg
Power 90-263VAC 47-63Hz fused T315mA Slo-Blo

Click here for further details: Clocks & Displays - TimeLord-Net

Manuals: TimeLord - Single-Zone Displays - Multi-Zone v1 Displays - Multi-Zone v2 Displays
Wharton, 4850, 4860, 482, 5200, 5400, 5600, NTP Time Server; LED digital clock, LCD digital clock, Moser-Baer, Mobatime, Gorgy, DTD5200, Leitch CSD5300, DTD5225, Alpermann and Velte, Evrtz, SC-303, SC-304, SC-305, MTD D25, Xli IEEE 1588 Grandmaster, Masterclock, Ledi; Symmetricom, Bodet, Kelio, Cristalys, Profil, world style clock, world clock, Veracity Timenet VTN-TN